PMD3051CH Pressure Transmitter Isolating Diaphragm

PMD3051CH pressure transmitter isolating diaphragm is a pressure measuring instrument suitable for the sanitary industry. It is suitable for measuring the pressure conditions of tanks or pipelines that require high sanitary conditions. It takes the atmospheric pressure (or pressure in the tank) as the pressure (differential pressure) signal measured at the reference end. The pressure signal can also reflect the height of the liquid. One port is a clamp, and the other end can also be a clamp or other connection. way) and process piping connection.

Parameter :

Medim liquid, gas, or steam
Measurement range 0~7000Kpa (0~70kgf/cm2), customized as request
Output signal 4 ~ 20mA dc, superimposed HART, RS485
Power supply 24V dc. , power range 12V ~ 45V
Accuracy + 0.1%, + 0.075%
Stability + 0.2% ≤ 12 months of the maximum range
Temperature range

electronic:-40 ~ 85 °C,sensitive element:-40 ~ 204 °C, storage temperature: -40 ~ 85 °C.

Temperature effect + 0.2% ≤ 20 °C with zero and range temperature error of maximum range
Power effect less than 0.005% / V of the output range.
Vibration effect on any axis, the frequency is 200Hz and the error is + 0.05% / g of the maximum range.
Load effect as long as the voltage of the input transmitter is higher than 12V, there is no load effect in the load working area.
Explosion-proof type flameproof ExdIIBT5Gb; Intrinsic safety ExiallCT4/T5/T6Ga;
Connection 1 1/2”, 2” or customized

Leave a Reply